smartctl 6.2 2013-07-26 r3841 [FreeBSD 9.2-RELEASE-p3 amd64] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD40EFRX-68WT0N0 Serial Number: WD-WMC4E0092788 LU WWN Device Id: 5 0014ee 2b424b9b7 Firmware Version: 80.00A80 User Capacity: 4,000,787,030,016 bytes [4.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Dec 5 22:48:48 2022 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (55920) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 559) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x703d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 181 176 021 Pre-fail Always - 7916 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 79 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0 9 Power_On_Hours 0x0032 066 066 000 Old_age Always - 24896 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 34 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 10 193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 692178 194 Temperature_Celsius 0x0022 121 116 000 Old_age Always - 31 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 18 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1370 - # 2 Short offline Completed without error 00% 1346 - # 3 Short offline Completed without error 00% 1322 - # 4 Short offline Completed without error 00% 1298 - # 5 Short offline Completed without error 00% 1274 - # 6 Short offline Completed without error 00% 1253 - # 7 Short offline Completed without error 00% 1226 - # 8 Short offline Completed without error 00% 1202 - # 9 Short offline Completed without error 00% 1178 - #10 Short offline Completed without error 00% 1154 - #11 Short offline Completed without error 00% 1130 - #12 Short offline Completed without error 00% 1106 - #13 Short offline Completed without error 00% 1082 - #14 Short offline Completed without error 00% 1058 - #15 Short offline Completed without error 00% 1035 - #16 Extended offline Completed without error 00% 1023 - #17 Short offline Completed without error 00% 1011 - #18 Short offline Completed without error 00% 987 - #19 Short offline Completed without error 00% 963 - #20 Short offline Completed without error 00% 939 - #21 Short offline Completed without error 00% 915 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.